Công nghệ sơn phủ tiên tiến

Cold Galvanized Paint

THINTECH COLD GALVANIZED PAINT is a single component, organic, zinc-rich coating containing 90% by weight of zinc dust pigment in the dried film.
Có sẵn:
0

Wet [µm]

0

Dry [µm]

0

m2/l

Cold Galvanized Paint

AIRLESS SPRAY

Recommended method of application TipSize:0.43–0.58mm(17–23thou) Pressure: 110 –160 kg/cm2 (1600 – 2300 psi)

Use an inbound pressure approximately 10 psi above the level at which “pig-tails” occur. Hose length should be limited to not more than 20 metres.

CONVENTIONAL AIR SPRAY

May be used. Use the lowest air pressure that will achieve good atomisation in order to minimise over-spray. The spray gun should be held about 8 inches (i.e. 20cm) from the surface, using a 6 to 8 inch (i.e. 15 – 20cm) spray fan.

USEFUL INFORMATIOM

THINNER: RT 7- 25 (Maximum 10% addition)

CLEANER: RT7-77

STORAGE: Store in a cool dry shaded area.

 

DRYING & CURING TIME

Substrate Temperature

Touch Dry

Hard Dry

Overcoating Interval Minimum*

Overcoating Interval Maximum

15 °C

35 minutes

21⁄2 hours

24 hours

Indefinite

25 °C

15 minutes

1 hour

16 hours

Indefinite

35 °C

10 minutes

30 minutes

10 hours

Indefinite

* The overcoating times given in the table are for a relative humidity level above 70%. Below 65% relative humidity, the overcoating intervals need to be doubled, i.e. 20 hours at 35°C.

SURFACE PREPARATION

  • The service life span and the service performance of THINTECH COLD GALVANIZED PAINT is directly related to the degree of surface preparation.
  • Remove all wax, oil and grease by solvent cleaning in accordance with the guidelines given by SSPC-SP1. Where necessary removes weld spatter and round off all rough weld seams and sharp edges to a smooth surface.
  • For steel, abrasive blast clean to a minimum standard of Sa2 or SSPC-SP6. For optimum performance, a blast to of Sa21⁄2 (ISO 8501- 1:1988) or SSPC-SP10 is recommended. An average surface profile of 50 microns is acceptable.
  • For Galvanizing, blast clean to minimum standard of Sa1 or SSPC-SP-7
  • Ensure that all surface defects detected after blast cleaning is ground, filled or treated in a suitable manner.
  • After blasting, remove dust from the surface. Ensure that the surface to be coated is clean, dry and free from any contaminants.
  • Apply Thintech Cold Galvanized Paint immediately after blasting to avoid oxidation and recontamination of the steel surface. In case of oxidation or recontamination, re-blast to the required standard.

To avoid condensation of moisture onto substrate prior to coating application, relative humidity should not exceed 85% and substrate temperature should be more than 3°C above Dew Point.